Skip to content
TaskNinja

HomeToolsPAN and OND File Viewer

PAN and OND File Viewer

Open PVsyst .PAN module and .OND inverter files with I-V curves and string sizing. Nothing is uploaded.

PanOpenFreeNo signupOn your device
Opening the tool…

What this tool does

PAN File Viewer opens a PVsyst solar module .PAN or inverter .OND file in this browser, draws its I-V, P-V and efficiency curves, and checks how many modules fit in a string.

How to use it

  1. Choose a .PAN module file, an .OND inverter file, or one of each together. Nothing is uploaded.

  2. Read the datasheet values: power, Voc, Isc, Vmp, Imp, temperature coefficients, cells, size and weight for a module; AC power, MPPT window, maximum DC voltage and efficiency for an inverter.

  3. Switch the module curves between irradiance and temperature, and between I-V and P-V. The table shows power, voltage and efficiency at low light, at a hot cell and at NOCT-like conditions.

  4. With both files open, set your site's lowest and hottest temperatures and see the shortest and longest string, the number of strings and the DC/AC ratio. Save a PDF datasheet, a PNG of the chart, or the specs and curves as CSV.

Common uses

Every PV module and inverter maker publishes a .PAN or .OND file so designers can simulate it in PVsyst, and banks, EPC contractors and owners ask for them in every tender. They are plain text, but full of keys such as RShunt, Gamma and muVocSpec, and PVsyst is a paid Windows program. A buyer comparing three module offers, a site engineer checking an inverter, or a student who was sent a .PAN file usually has nothing to open it with.

This page reads the file the way PVsyst does. For a module it rebuilds the one-diode model from the stored series and shunt resistance, diode ideality and its temperature coefficient, so the I-V curves at 200 or 600 W/m² and at 50 or 75 °C come from the same equations PVsyst uses, not from a straight-line guess. The model power at STC is shown next to the nameplate, so a badly made .PAN file stands out at once.

For an inverter it draws the efficiency profile at each input voltage stored in the file, and lists the MPPT voltage window, the absolute maximum input voltage, the maximum DC current, the number of MPPT inputs and the power limits at high temperature.

Open a module and an inverter together and the string check runs the same tests as PVsyst's sizing dialog: the open-circuit voltage at the coldest temperature against the inverter and module voltage limits, the MPP voltage in summer and winter against the MPPT window, and the string current against the inverter's maximum input current.

Private, and the limits

Manufacturer files under NDA and project files stay on your device. The file is read by a worker in this browser tab and the PDF, PNG and CSV files are made on your computer. There is no upload and no account.

Curves are calculated from the file with the published PVsyst model, so they match PVsyst closely but they are not measurements. The string check covers voltages and currents only; it is not a full system design.

Official sources

Last checked 2026-11-17.

FAQ

How do I open a .PAN file without PVsyst?
Choose the file on this page. It opens in Chrome, Edge, Firefox or Safari on Windows, Mac, Linux, Android or iPhone, with nothing to install and no PVsyst licence.
Is a .PAN file the same as a PAN card?
No. A PVsyst .PAN file describes a solar panel. If you were looking for an Indian PAN card PDF or photo, this page cannot open it; use a PDF or image viewer instead.
Do the curves match PVsyst?
They use the same one-diode model with the same parameters, including the shunt resistance that changes with light and the recombination term for thin-film modules. We checked the results against the open source pvlib library on more than 70 real .PAN files; the power at STC agrees with the nameplate within about 1 percent.
Can it open PVsyst project files?
No. Project and variant files (.PRJ, .VC0 and so on) and meteo files are binary and only PVsyst can read them. Open the .PAN and .OND files from the project's components folder instead.
Which versions work?
Text .PAN and .OND files from PVsyst 6, 7 and 8, including bifacial modules, thin-film modules, inverters with several efficiency curves and files saved with non-English characters.
Can I edit the file?
Not on this page. It is a viewer. You can copy every value from the parameter list or download them as CSV.

Related tools

OND and PAN to PDFSTAAD File ViewerAll tools